mirror of
https://git.savannah.gnu.org/git/guile.git
synced 2025-04-30 20:00:19 +02:00
* libguile/array-handle.c: * libguile/bytevectors.c: * libguile/deprecated.c: * libguile/eval.c: * libguile/feature.c: * libguile/filesys.c: * libguile/gc.c: * libguile/gdbint.c: * libguile/goops.c: * libguile/instructions.c: * libguile/load.c: * libguile/modules.c: * libguile/numbers.c: * libguile/options.c: * libguile/ports.c: * libguile/scmsigs.c: * libguile/srcprop.c: * libguile/srfi-4.c: * libguile/stacks.c: * libguile/threads.c: * libguile/vm.c: Remove calls to scm_permanent_object, as they are no longer needed with the BDW GC.
709 lines
21 KiB
C
709 lines
21 KiB
C
/* Copyright (C) 1995,1996,1997,1998,1999,2000,2001, 2002, 2004, 2006, 2007, 2008, 2009 Free Software Foundation, Inc.
|
||
*
|
||
* This library is free software; you can redistribute it and/or
|
||
* modify it under the terms of the GNU Lesser General Public License
|
||
* as published by the Free Software Foundation; either version 3 of
|
||
* the License, or (at your option) any later version.
|
||
*
|
||
* This library is distributed in the hope that it will be useful, but
|
||
* WITHOUT ANY WARRANTY; without even the implied warranty of
|
||
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
|
||
* Lesser General Public License for more details.
|
||
*
|
||
* You should have received a copy of the GNU Lesser General Public
|
||
* License along with this library; if not, write to the Free Software
|
||
* Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston, MA
|
||
* 02110-1301 USA
|
||
*/
|
||
|
||
|
||
|
||
|
||
#ifdef HAVE_CONFIG_H
|
||
# include <config.h>
|
||
#endif
|
||
|
||
#include <fcntl.h> /* for mingw */
|
||
#include <signal.h>
|
||
#include <stdio.h>
|
||
#include <errno.h>
|
||
|
||
#include "libguile/_scm.h"
|
||
|
||
#include "libguile/async.h"
|
||
#include "libguile/eval.h"
|
||
#include "libguile/root.h"
|
||
#include "libguile/vectors.h"
|
||
#include "libguile/threads.h"
|
||
|
||
#include "libguile/validate.h"
|
||
#include "libguile/scmsigs.h"
|
||
|
||
#ifdef HAVE_IO_H
|
||
#include <io.h> /* for mingw _pipe() */
|
||
#endif
|
||
|
||
#ifdef HAVE_PROCESS_H
|
||
#include <process.h> /* for mingw */
|
||
#endif
|
||
|
||
#ifdef HAVE_UNISTD_H
|
||
#include <unistd.h>
|
||
#endif
|
||
|
||
#ifdef HAVE_SYS_TIME_H
|
||
#include <sys/time.h>
|
||
#endif
|
||
|
||
#ifdef __MINGW32__
|
||
#include <windows.h>
|
||
#define alarm(sec) (0)
|
||
/* This weird comma expression is because Sleep is void under Windows. */
|
||
#define sleep(sec) (Sleep ((sec) * 1000), 0)
|
||
#define usleep(usec) (Sleep ((usec) / 1000), 0)
|
||
#define pipe(fd) _pipe (fd, 256, O_BINARY)
|
||
#endif
|
||
|
||
#include <full-write.h>
|
||
|
||
|
||
|
||
|
||
/* SIGRETTYPE is the type that signal handlers return. See <signal.h> */
|
||
|
||
#ifdef RETSIGTYPE
|
||
# define SIGRETTYPE RETSIGTYPE
|
||
#else
|
||
# ifdef STDC_HEADERS
|
||
# define SIGRETTYPE void
|
||
# else
|
||
# define SIGRETTYPE int
|
||
# endif
|
||
#endif
|
||
|
||
|
||
|
||
/* take_signal is installed as the C signal handler whenever a Scheme
|
||
handler is set. When a signal arrives, take_signal will write a
|
||
byte into the 'signal pipe'. The 'signal delivery thread' will
|
||
read this pipe and queue the appropriate asyncs.
|
||
|
||
When Guile is built without threads, the signal handler will
|
||
install the async directly.
|
||
*/
|
||
|
||
|
||
/* Scheme vectors with information about a signal. signal_handlers
|
||
contains the handler procedure or #f, signal_handler_asyncs
|
||
contains the thunk to be marked as an async when the signal arrives
|
||
(or the cell with the thunk in a singlethreaded Guile), and
|
||
signal_handler_threads points to the thread that a signal should be
|
||
delivered to.
|
||
*/
|
||
static SCM *signal_handlers;
|
||
static SCM signal_handler_asyncs;
|
||
static SCM signal_handler_threads;
|
||
|
||
/* The signal delivery thread. */
|
||
scm_i_thread *scm_i_signal_delivery_thread = NULL;
|
||
|
||
/* The mutex held when launching the signal delivery thread. */
|
||
static scm_i_pthread_mutex_t signal_delivery_thread_mutex =
|
||
SCM_I_PTHREAD_MUTEX_INITIALIZER;
|
||
|
||
|
||
/* saves the original C handlers, when a new handler is installed.
|
||
set to SIG_ERR if the original handler is installed. */
|
||
#ifdef HAVE_SIGACTION
|
||
static struct sigaction orig_handlers[NSIG];
|
||
#else
|
||
static SIGRETTYPE (*orig_handlers[NSIG])(int);
|
||
#endif
|
||
|
||
static SCM
|
||
close_1 (SCM proc, SCM arg)
|
||
{
|
||
return scm_primitive_eval_x (scm_list_3 (scm_sym_lambda, SCM_EOL,
|
||
scm_list_2 (proc, arg)));
|
||
}
|
||
|
||
#if SCM_USE_PTHREAD_THREADS
|
||
/* On mingw there's no notion of inter-process signals, only a raise()
|
||
within the process itself which apparently invokes the registered handler
|
||
immediately. Not sure how well the following code will cope in this
|
||
case. It builds but it may not offer quite the same scheme-level
|
||
semantics as on a proper system. If you're relying on much in the way of
|
||
signal handling on mingw you probably lose anyway. */
|
||
|
||
static int signal_pipe[2];
|
||
|
||
static SIGRETTYPE
|
||
take_signal (int signum)
|
||
{
|
||
char sigbyte = signum;
|
||
full_write (signal_pipe[1], &sigbyte, 1);
|
||
|
||
#ifndef HAVE_SIGACTION
|
||
signal (signum, take_signal);
|
||
#endif
|
||
}
|
||
|
||
static SCM
|
||
signal_delivery_thread (void *data)
|
||
{
|
||
int n, sig;
|
||
char sigbyte;
|
||
#if HAVE_PTHREAD_SIGMASK /* not on mingw, see notes above */
|
||
sigset_t all_sigs;
|
||
sigfillset (&all_sigs);
|
||
scm_i_pthread_sigmask (SIG_SETMASK, &all_sigs, NULL);
|
||
#endif
|
||
|
||
while (1)
|
||
{
|
||
n = read (signal_pipe[0], &sigbyte, 1);
|
||
sig = sigbyte;
|
||
if (n == 1 && sig >= 0 && sig < NSIG)
|
||
{
|
||
SCM h, t;
|
||
|
||
h = SCM_SIMPLE_VECTOR_REF (signal_handler_asyncs, sig);
|
||
t = SCM_SIMPLE_VECTOR_REF (signal_handler_threads, sig);
|
||
if (scm_is_true (h))
|
||
scm_system_async_mark_for_thread (h, t);
|
||
}
|
||
else if (n == 0)
|
||
break; /* the signal pipe was closed. */
|
||
else if (n < 0 && errno != EINTR)
|
||
perror ("error in signal delivery thread");
|
||
}
|
||
|
||
return SCM_UNSPECIFIED; /* not reached unless all other threads exited */
|
||
}
|
||
|
||
static void
|
||
start_signal_delivery_thread (void)
|
||
{
|
||
SCM signal_thread;
|
||
|
||
scm_i_pthread_mutex_lock (&signal_delivery_thread_mutex);
|
||
|
||
if (pipe (signal_pipe) != 0)
|
||
scm_syserror (NULL);
|
||
signal_thread = scm_spawn_thread (signal_delivery_thread, NULL,
|
||
scm_handle_by_message,
|
||
"signal delivery thread");
|
||
scm_i_signal_delivery_thread = SCM_I_THREAD_DATA (signal_thread);
|
||
|
||
scm_i_pthread_mutex_unlock (&signal_delivery_thread_mutex);
|
||
}
|
||
|
||
void
|
||
scm_i_ensure_signal_delivery_thread ()
|
||
{
|
||
static scm_i_pthread_once_t once = SCM_I_PTHREAD_ONCE_INIT;
|
||
scm_i_pthread_once (&once, start_signal_delivery_thread);
|
||
}
|
||
|
||
#else /* !SCM_USE_PTHREAD_THREADS */
|
||
|
||
static SIGRETTYPE
|
||
take_signal (int signum)
|
||
{
|
||
SCM cell = SCM_SIMPLE_VECTOR_REF (signal_handler_asyncs, signum);
|
||
scm_i_thread *t = SCM_I_CURRENT_THREAD;
|
||
|
||
if (scm_is_false (SCM_CDR (cell)))
|
||
{
|
||
SCM_SETCDR (cell, t->active_asyncs);
|
||
t->active_asyncs = cell;
|
||
t->pending_asyncs = 1;
|
||
}
|
||
|
||
#ifndef HAVE_SIGACTION
|
||
signal (signum, take_signal);
|
||
#endif
|
||
}
|
||
|
||
void
|
||
scm_i_ensure_signal_delivery_thread ()
|
||
{
|
||
return;
|
||
}
|
||
|
||
#endif /* !SCM_USE_PTHREAD_THREADS */
|
||
|
||
static void
|
||
install_handler (int signum, SCM thread, SCM handler)
|
||
{
|
||
if (scm_is_false (handler))
|
||
{
|
||
SCM_SIMPLE_VECTOR_SET (*signal_handlers, signum, SCM_BOOL_F);
|
||
SCM_SIMPLE_VECTOR_SET (signal_handler_asyncs, signum, SCM_BOOL_F);
|
||
}
|
||
else
|
||
{
|
||
SCM async = close_1 (handler, scm_from_int (signum));
|
||
#if !SCM_USE_PTHREAD_THREADS
|
||
async = scm_cons (async, SCM_BOOL_F);
|
||
#endif
|
||
SCM_SIMPLE_VECTOR_SET (*signal_handlers, signum, handler);
|
||
SCM_SIMPLE_VECTOR_SET (signal_handler_asyncs, signum, async);
|
||
}
|
||
|
||
SCM_SIMPLE_VECTOR_SET (signal_handler_threads, signum, thread);
|
||
}
|
||
|
||
SCM
|
||
scm_sigaction (SCM signum, SCM handler, SCM flags)
|
||
{
|
||
return scm_sigaction_for_thread (signum, handler, flags, SCM_UNDEFINED);
|
||
}
|
||
|
||
/* user interface for installation of signal handlers. */
|
||
SCM_DEFINE (scm_sigaction_for_thread, "sigaction", 1, 3, 0,
|
||
(SCM signum, SCM handler, SCM flags, SCM thread),
|
||
"Install or report the signal handler for a specified signal.\n\n"
|
||
"@var{signum} is the signal number, which can be specified using the value\n"
|
||
"of variables such as @code{SIGINT}.\n\n"
|
||
"If @var{handler} is omitted, @code{sigaction} returns a pair: the\n"
|
||
"CAR is the current\n"
|
||
"signal hander, which will be either an integer with the value @code{SIG_DFL}\n"
|
||
"(default action) or @code{SIG_IGN} (ignore), or the Scheme procedure which\n"
|
||
"handles the signal, or @code{#f} if a non-Scheme procedure handles the\n"
|
||
"signal. The CDR contains the current @code{sigaction} flags for the handler.\n\n"
|
||
"If @var{handler} is provided, it is installed as the new handler for\n"
|
||
"@var{signum}. @var{handler} can be a Scheme procedure taking one\n"
|
||
"argument, or the value of @code{SIG_DFL} (default action) or\n"
|
||
"@code{SIG_IGN} (ignore), or @code{#f} to restore whatever signal handler\n"
|
||
"was installed before @code{sigaction} was first used. When\n"
|
||
"a scheme procedure has been specified, that procedure will run\n"
|
||
"in the given @var{thread}. When no thread has been given, the\n"
|
||
"thread that made this call to @code{sigaction} is used.\n"
|
||
"Flags can optionally be specified for the new handler.\n"
|
||
"The return value is a pair with information about the\n"
|
||
"old handler as described above.\n\n"
|
||
"This interface does not provide access to the \"signal blocking\"\n"
|
||
"facility. Maybe this is not needed, since the thread support may\n"
|
||
"provide solutions to the problem of consistent access to data\n"
|
||
"structures.")
|
||
#define FUNC_NAME s_scm_sigaction_for_thread
|
||
{
|
||
int csig;
|
||
#ifdef HAVE_SIGACTION
|
||
struct sigaction action;
|
||
struct sigaction old_action;
|
||
#else
|
||
SIGRETTYPE (* chandler) (int) = SIG_DFL;
|
||
SIGRETTYPE (* old_chandler) (int);
|
||
#endif
|
||
int query_only = 0;
|
||
int save_handler = 0;
|
||
|
||
SCM old_handler;
|
||
|
||
csig = scm_to_signed_integer (signum, 0, NSIG-1);
|
||
|
||
#if defined(HAVE_SIGACTION)
|
||
action.sa_flags = 0;
|
||
if (!SCM_UNBNDP (flags))
|
||
action.sa_flags |= scm_to_int (flags);
|
||
sigemptyset (&action.sa_mask);
|
||
#endif
|
||
|
||
if (SCM_UNBNDP (thread))
|
||
thread = scm_current_thread ();
|
||
else
|
||
{
|
||
SCM_VALIDATE_THREAD (4, thread);
|
||
if (scm_c_thread_exited_p (thread))
|
||
SCM_MISC_ERROR ("thread has already exited", SCM_EOL);
|
||
}
|
||
|
||
scm_i_ensure_signal_delivery_thread ();
|
||
|
||
SCM_CRITICAL_SECTION_START;
|
||
old_handler = SCM_SIMPLE_VECTOR_REF (*signal_handlers, csig);
|
||
if (SCM_UNBNDP (handler))
|
||
query_only = 1;
|
||
else if (scm_is_integer (handler))
|
||
{
|
||
long handler_int = scm_to_long (handler);
|
||
|
||
if (handler_int == (long) SIG_DFL || handler_int == (long) SIG_IGN)
|
||
{
|
||
#ifdef HAVE_SIGACTION
|
||
action.sa_handler = (SIGRETTYPE (*) (int)) handler_int;
|
||
#else
|
||
chandler = (SIGRETTYPE (*) (int)) handler_int;
|
||
#endif
|
||
install_handler (csig, SCM_BOOL_F, SCM_BOOL_F);
|
||
}
|
||
else
|
||
{
|
||
SCM_CRITICAL_SECTION_END;
|
||
SCM_OUT_OF_RANGE (2, handler);
|
||
}
|
||
}
|
||
else if (scm_is_false (handler))
|
||
{
|
||
/* restore the default handler. */
|
||
#ifdef HAVE_SIGACTION
|
||
if (orig_handlers[csig].sa_handler == SIG_ERR)
|
||
query_only = 1;
|
||
else
|
||
{
|
||
action = orig_handlers[csig];
|
||
orig_handlers[csig].sa_handler = SIG_ERR;
|
||
install_handler (csig, SCM_BOOL_F, SCM_BOOL_F);
|
||
}
|
||
#else
|
||
if (orig_handlers[csig] == SIG_ERR)
|
||
query_only = 1;
|
||
else
|
||
{
|
||
chandler = orig_handlers[csig];
|
||
orig_handlers[csig] = SIG_ERR;
|
||
install_handler (csig, SCM_BOOL_F, SCM_BOOL_F);
|
||
}
|
||
#endif
|
||
}
|
||
else
|
||
{
|
||
SCM_VALIDATE_PROC (2, handler);
|
||
#ifdef HAVE_SIGACTION
|
||
action.sa_handler = take_signal;
|
||
if (orig_handlers[csig].sa_handler == SIG_ERR)
|
||
save_handler = 1;
|
||
#else
|
||
chandler = take_signal;
|
||
if (orig_handlers[csig] == SIG_ERR)
|
||
save_handler = 1;
|
||
#endif
|
||
install_handler (csig, thread, handler);
|
||
}
|
||
|
||
/* XXX - Silently ignore setting handlers for `program error signals'
|
||
because they can't currently be handled by Scheme code.
|
||
*/
|
||
|
||
switch (csig)
|
||
{
|
||
/* This list of program error signals is from the GNU Libc
|
||
Reference Manual */
|
||
case SIGFPE:
|
||
case SIGILL:
|
||
case SIGSEGV:
|
||
#ifdef SIGBUS
|
||
case SIGBUS:
|
||
#endif
|
||
case SIGABRT:
|
||
#if defined(SIGIOT) && (SIGIOT != SIGABRT)
|
||
case SIGIOT:
|
||
#endif
|
||
#ifdef SIGTRAP
|
||
case SIGTRAP:
|
||
#endif
|
||
#ifdef SIGEMT
|
||
case SIGEMT:
|
||
#endif
|
||
#ifdef SIGSYS
|
||
case SIGSYS:
|
||
#endif
|
||
query_only = 1;
|
||
}
|
||
|
||
#ifdef HAVE_SIGACTION
|
||
if (query_only)
|
||
{
|
||
if (sigaction (csig, 0, &old_action) == -1)
|
||
SCM_SYSERROR;
|
||
}
|
||
else
|
||
{
|
||
if (sigaction (csig, &action , &old_action) == -1)
|
||
SCM_SYSERROR;
|
||
if (save_handler)
|
||
orig_handlers[csig] = old_action;
|
||
}
|
||
if (old_action.sa_handler == SIG_DFL || old_action.sa_handler == SIG_IGN)
|
||
old_handler = scm_from_long ((long) old_action.sa_handler);
|
||
SCM_CRITICAL_SECTION_END;
|
||
return scm_cons (old_handler, scm_from_int (old_action.sa_flags));
|
||
#else
|
||
if (query_only)
|
||
{
|
||
if ((old_chandler = signal (csig, SIG_IGN)) == SIG_ERR)
|
||
SCM_SYSERROR;
|
||
if (signal (csig, old_chandler) == SIG_ERR)
|
||
SCM_SYSERROR;
|
||
}
|
||
else
|
||
{
|
||
if ((old_chandler = signal (csig, chandler)) == SIG_ERR)
|
||
SCM_SYSERROR;
|
||
if (save_handler)
|
||
orig_handlers[csig] = old_chandler;
|
||
}
|
||
if (old_chandler == SIG_DFL || old_chandler == SIG_IGN)
|
||
old_handler = scm_from_long ((long) old_chandler);
|
||
SCM_CRITICAL_SECTION_END;
|
||
return scm_cons (old_handler, scm_from_int (0));
|
||
#endif
|
||
}
|
||
#undef FUNC_NAME
|
||
|
||
SCM_DEFINE (scm_restore_signals, "restore-signals", 0, 0, 0,
|
||
(void),
|
||
"Return all signal handlers to the values they had before any call to\n"
|
||
"@code{sigaction} was made. The return value is unspecified.")
|
||
#define FUNC_NAME s_scm_restore_signals
|
||
{
|
||
int i;
|
||
for (i = 0; i < NSIG; i++)
|
||
{
|
||
#ifdef HAVE_SIGACTION
|
||
if (orig_handlers[i].sa_handler != SIG_ERR)
|
||
{
|
||
if (sigaction (i, &orig_handlers[i], NULL) == -1)
|
||
SCM_SYSERROR;
|
||
orig_handlers[i].sa_handler = SIG_ERR;
|
||
SCM_SIMPLE_VECTOR_SET (*signal_handlers, i, SCM_BOOL_F);
|
||
}
|
||
#else
|
||
if (orig_handlers[i] != SIG_ERR)
|
||
{
|
||
if (signal (i, orig_handlers[i]) == SIG_ERR)
|
||
SCM_SYSERROR;
|
||
orig_handlers[i] = SIG_ERR;
|
||
SCM_SIMPLE_VECTOR_SET (*signal_handlers, i, SCM_BOOL_F);
|
||
}
|
||
#endif
|
||
}
|
||
return SCM_UNSPECIFIED;
|
||
}
|
||
#undef FUNC_NAME
|
||
|
||
SCM_DEFINE (scm_alarm, "alarm", 1, 0, 0,
|
||
(SCM i),
|
||
"Set a timer to raise a @code{SIGALRM} signal after the specified\n"
|
||
"number of seconds (an integer). It's advisable to install a signal\n"
|
||
"handler for\n"
|
||
"@code{SIGALRM} beforehand, since the default action is to terminate\n"
|
||
"the process.\n\n"
|
||
"The return value indicates the time remaining for the previous alarm,\n"
|
||
"if any. The new value replaces the previous alarm. If there was\n"
|
||
"no previous alarm, the return value is zero.")
|
||
#define FUNC_NAME s_scm_alarm
|
||
{
|
||
return scm_from_uint (alarm (scm_to_uint (i)));
|
||
}
|
||
#undef FUNC_NAME
|
||
|
||
#ifdef HAVE_SETITIMER
|
||
SCM_DEFINE (scm_setitimer, "setitimer", 5, 0, 0,
|
||
(SCM which_timer,
|
||
SCM interval_seconds, SCM interval_microseconds,
|
||
SCM value_seconds, SCM value_microseconds),
|
||
"Set the timer specified by @var{which_timer} according to the given\n"
|
||
"@var{interval_seconds}, @var{interval_microseconds},\n"
|
||
"@var{value_seconds}, and @var{value_microseconds} values.\n"
|
||
"\n"
|
||
"Return information about the timer's previous setting."
|
||
"\n"
|
||
"Errors are handled as described in the guile info pages under ``POSIX\n"
|
||
"Interface Conventions''.\n"
|
||
"\n"
|
||
"The timers available are: @code{ITIMER_REAL}, @code{ITIMER_VIRTUAL},\n"
|
||
"and @code{ITIMER_PROF}.\n"
|
||
"\n"
|
||
"The return value will be a list of two cons pairs representing the\n"
|
||
"current state of the given timer. The first pair is the seconds and\n"
|
||
"microseconds of the timer @code{it_interval}, and the second pair is\n"
|
||
"the seconds and microseconds of the timer @code{it_value}.")
|
||
#define FUNC_NAME s_scm_setitimer
|
||
{
|
||
int rv;
|
||
int c_which_timer;
|
||
struct itimerval new_timer;
|
||
struct itimerval old_timer;
|
||
|
||
c_which_timer = SCM_NUM2INT(1, which_timer);
|
||
new_timer.it_interval.tv_sec = SCM_NUM2LONG(2, interval_seconds);
|
||
new_timer.it_interval.tv_usec = SCM_NUM2LONG(3, interval_microseconds);
|
||
new_timer.it_value.tv_sec = SCM_NUM2LONG(4, value_seconds);
|
||
new_timer.it_value.tv_usec = SCM_NUM2LONG(5, value_microseconds);
|
||
|
||
SCM_SYSCALL(rv = setitimer(c_which_timer, &new_timer, &old_timer));
|
||
|
||
if(rv != 0)
|
||
SCM_SYSERROR;
|
||
|
||
return scm_list_2 (scm_cons (scm_from_long (old_timer.it_interval.tv_sec),
|
||
scm_from_long (old_timer.it_interval.tv_usec)),
|
||
scm_cons (scm_from_long (old_timer.it_value.tv_sec),
|
||
scm_from_long (old_timer.it_value.tv_usec)));
|
||
}
|
||
#undef FUNC_NAME
|
||
#endif /* HAVE_SETITIMER */
|
||
|
||
#ifdef HAVE_GETITIMER
|
||
SCM_DEFINE (scm_getitimer, "getitimer", 1, 0, 0,
|
||
(SCM which_timer),
|
||
"Return information about the timer specified by @var{which_timer}"
|
||
"\n"
|
||
"Errors are handled as described in the guile info pages under ``POSIX\n"
|
||
"Interface Conventions''.\n"
|
||
"\n"
|
||
"The timers available are: @code{ITIMER_REAL}, @code{ITIMER_VIRTUAL},\n"
|
||
"and @code{ITIMER_PROF}.\n"
|
||
"\n"
|
||
"The return value will be a list of two cons pairs representing the\n"
|
||
"current state of the given timer. The first pair is the seconds and\n"
|
||
"microseconds of the timer @code{it_interval}, and the second pair is\n"
|
||
"the seconds and microseconds of the timer @code{it_value}.")
|
||
#define FUNC_NAME s_scm_getitimer
|
||
{
|
||
int rv;
|
||
int c_which_timer;
|
||
struct itimerval old_timer;
|
||
|
||
c_which_timer = SCM_NUM2INT(1, which_timer);
|
||
|
||
SCM_SYSCALL(rv = getitimer(c_which_timer, &old_timer));
|
||
|
||
if(rv != 0)
|
||
SCM_SYSERROR;
|
||
|
||
return scm_list_2 (scm_cons (scm_from_long (old_timer.it_interval.tv_sec),
|
||
scm_from_long (old_timer.it_interval.tv_usec)),
|
||
scm_cons (scm_from_long (old_timer.it_value.tv_sec),
|
||
scm_from_long (old_timer.it_value.tv_usec)));
|
||
}
|
||
#undef FUNC_NAME
|
||
#endif /* HAVE_GETITIMER */
|
||
|
||
#ifdef HAVE_PAUSE
|
||
SCM_DEFINE (scm_pause, "pause", 0, 0, 0,
|
||
(),
|
||
"Pause the current process (thread?) until a signal arrives whose\n"
|
||
"action is to either terminate the current process or invoke a\n"
|
||
"handler procedure. The return value is unspecified.")
|
||
#define FUNC_NAME s_scm_pause
|
||
{
|
||
pause ();
|
||
return SCM_UNSPECIFIED;
|
||
}
|
||
#undef FUNC_NAME
|
||
#endif
|
||
|
||
SCM_DEFINE (scm_sleep, "sleep", 1, 0, 0,
|
||
(SCM i),
|
||
"Wait for the given number of seconds (an integer) or until a signal\n"
|
||
"arrives. The return value is zero if the time elapses or the number\n"
|
||
"of seconds remaining otherwise.\n"
|
||
"\n"
|
||
"See also @code{usleep}.")
|
||
#define FUNC_NAME s_scm_sleep
|
||
{
|
||
return scm_from_uint (scm_std_sleep (scm_to_uint (i)));
|
||
}
|
||
#undef FUNC_NAME
|
||
|
||
SCM_DEFINE (scm_usleep, "usleep", 1, 0, 0,
|
||
(SCM i),
|
||
"Wait the given period @var{usecs} microseconds (an integer).\n"
|
||
"If a signal arrives the wait stops and the return value is the\n"
|
||
"time remaining, in microseconds. If the period elapses with no\n"
|
||
"signal the return is zero.\n"
|
||
"\n"
|
||
"On most systems the process scheduler is not microsecond accurate and\n"
|
||
"the actual period slept by @code{usleep} may be rounded to a system\n"
|
||
"clock tick boundary. Traditionally such ticks were 10 milliseconds\n"
|
||
"apart, and that interval is often still used.\n"
|
||
"\n"
|
||
"See also @code{sleep}.")
|
||
#define FUNC_NAME s_scm_usleep
|
||
{
|
||
return scm_from_ulong (scm_std_usleep (scm_to_ulong (i)));
|
||
}
|
||
#undef FUNC_NAME
|
||
|
||
SCM_DEFINE (scm_raise, "raise", 1, 0, 0,
|
||
(SCM sig),
|
||
"Sends a specified signal @var{sig} to the current process, where\n"
|
||
"@var{sig} is as described for the kill procedure.")
|
||
#define FUNC_NAME s_scm_raise
|
||
{
|
||
if (raise (scm_to_int (sig)) != 0)
|
||
SCM_SYSERROR;
|
||
return SCM_UNSPECIFIED;
|
||
}
|
||
#undef FUNC_NAME
|
||
|
||
|
||
|
||
void
|
||
scm_i_close_signal_pipe()
|
||
{
|
||
/* SIGNAL_DELIVERY_THREAD_MUTEX is only locked while the signal delivery
|
||
thread is being launched. The thread that calls this function is
|
||
already holding the thread admin mutex, so if the delivery thread hasn't
|
||
been launched at this point, it never will be before shutdown. */
|
||
scm_i_pthread_mutex_lock (&signal_delivery_thread_mutex);
|
||
|
||
#if SCM_USE_PTHREAD_THREADS
|
||
if (scm_i_signal_delivery_thread != NULL)
|
||
close (signal_pipe[1]);
|
||
#endif
|
||
|
||
scm_i_pthread_mutex_unlock (&signal_delivery_thread_mutex);
|
||
}
|
||
|
||
void
|
||
scm_init_scmsigs ()
|
||
{
|
||
int i;
|
||
|
||
signal_handlers =
|
||
SCM_VARIABLE_LOC (scm_c_define ("signal-handlers",
|
||
scm_c_make_vector (NSIG, SCM_BOOL_F)));
|
||
signal_handler_asyncs = scm_c_make_vector (NSIG, SCM_BOOL_F);
|
||
signal_handler_threads = scm_c_make_vector (NSIG, SCM_BOOL_F);
|
||
|
||
for (i = 0; i < NSIG; i++)
|
||
{
|
||
#ifdef HAVE_SIGACTION
|
||
orig_handlers[i].sa_handler = SIG_ERR;
|
||
|
||
#else
|
||
orig_handlers[i] = SIG_ERR;
|
||
#endif
|
||
}
|
||
|
||
scm_c_define ("NSIG", scm_from_long (NSIG));
|
||
scm_c_define ("SIG_IGN", scm_from_long ((long) SIG_IGN));
|
||
scm_c_define ("SIG_DFL", scm_from_long ((long) SIG_DFL));
|
||
#ifdef SA_NOCLDSTOP
|
||
scm_c_define ("SA_NOCLDSTOP", scm_from_long (SA_NOCLDSTOP));
|
||
#endif
|
||
#ifdef SA_RESTART
|
||
scm_c_define ("SA_RESTART", scm_from_long (SA_RESTART));
|
||
#endif
|
||
|
||
#if defined(HAVE_SETITIMER) || defined(HAVE_GETITIMER)
|
||
/* Stuff needed by setitimer and getitimer. */
|
||
scm_c_define ("ITIMER_REAL", scm_from_int (ITIMER_REAL));
|
||
scm_c_define ("ITIMER_VIRTUAL", scm_from_int (ITIMER_VIRTUAL));
|
||
scm_c_define ("ITIMER_PROF", scm_from_int (ITIMER_PROF));
|
||
#endif /* defined(HAVE_SETITIMER) || defined(HAVE_GETITIMER) */
|
||
|
||
#include "libguile/scmsigs.x"
|
||
}
|
||
|
||
|
||
/*
|
||
Local Variables:
|
||
c-file-style: "gnu"
|
||
End:
|
||
*/
|